UL 50E rain test apparatus for NEMA 250 Type 3R enclosures

NEMA Enclosure Types 3R, 4, 4X, 12 and Others: Which Test Proves Each Rating (NEMA 250 / UL 50E)

Nov 4
5 min read

A NEMA Type is not a list of features. It is a promise that the enclosure passed a defined set of tests. A Type 3R box was tested in rain, a Type 4X box was tested under a hose and in salt spray, and a Type 12 box was tested against circulating dust. If you build or certify enclosures for North America, the Type tells you exactly which tests to run. This note goes through each Type and the test behind it, using the clause numbers of NEMA 250-2018. UL 50E and CSA C22.2 No. 94.2 are harmonized with it and use the same tests.

IP codes and NEMA Types are not interchangeable

NEMA 250 Table 5-1C gives the IP second numeral that corresponds to each Type: 3R to IPX4, 3 and 3S to IPX5, 4 and 4X to IPX6, 6 to IPX7 and 6P to IPX8. The link works in one direction only. IEC 60529 allows some water inside at numerals 5, 6, 7 and 8 if it does no harm; NEMA 250 allows none when the same test is used to earn a Type. A Type also adds requirements that no IP code covers: corrosion protection, external icing, oil, gaskets and construction. An IP66 enclosure therefore cannot be called Type 4 on the strength of its IP test.

Which Type needs which test

  • Type 1: indoor, no water test. Indoor corrosion protection only (5.8).

  • Type 2: dripping and light splashing, drip test 5.3.

  • Type 3R and 3RX: rain test 5.4, external icing 5.6, outdoor corrosion 5.9. The X adds the special corrosion test 5.10.

  • Type 3 and 3X: windblown dust test 5.5.1. Vented enclosures may use the hose method of 5.5.1 or the rain test 5.4. External icing and corrosion as for 3R.

  • Type 3S and 3SX: as Type 3, but the icing test 5.6 is run with the external mechanisms, which must still be operable by one person while ice-laden.

  • Type 4 and 4X: hosedown test 5.7, external icing, corrosion; 4X adds the special corrosion test.

  • Type 5: settling dust test 5.5.2.2, or for vented enclosures the atomized water method B or the drip test 5.3.

  • Type 6: hosedown 5.7 plus temporary submersion 5.11.

  • Type 6P: hosedown 5.7 plus prolonged submersion 5.12, and the special corrosion test.

  • Type 12 and 12K: circulating dust test 5.5.2.1, or for vented enclosures the atomized water method A or the drip test 5.3; the K version has knockouts.

  • Type 13: oil exclusion test 5.13.

Types 7 and 9 are explosion-proof and dust-ignition-proof enclosures under UL 1203 and are outside NEMA 250's water and dust tests.

Drip test (5.3): Types 2, 5, 12, 12K

Water drips onto the top of the enclosure from a grid of sources: one source for every 129 cm² (20 in²), at least 20 drops per minute per source, for 30 minutes, with the drip area extending beyond every exposed side of the enclosure. The pitch is much coarser than the 20 × 20 mm grid of an IEC 60529 drip box, so an IPX1/IPX2 drip box cannot simply be reused. Our DripTile 250 modular drip box is built on the 4″ × 5″ grid of 5.3 and joins in 508 mm modules so the array can overhang large enclosures.

Rain test (5.4): Types 3R and 3RX, and vented Types 3 and 3S

The rain test uses at least three spray heads on a pipe rack (Figure 5-1), each built to the drawing of Figure 5-2 and fed at 34.5 kPa (5 psi). The enclosure sits in the focal area where the most water is likely to enter, and the spray runs continuously for one hour. Conduit is connected and tightened to the torques of Table 5-2 before the test. The enclosure passes if no water accumulates inside and none has reached a level higher than the lowest live part. The geometry of the spray heads decides the result, so they should be checked against the drawing before every campaign. See the UL 50E spray test apparatus for the NEMA 250 rain test and the replacement rain-test spray head elements.

Hosedown test (5.7): Types 4, 4X, 6 and 6P

A 25 mm (1 in) nozzle delivers at least 240 L/min (65 gal/min) from 3.0 to 3.5 m. The stream is directed at every seam, joint and external mechanism, moving along each one once at about 6 mm/s. No water may enter. The hose method of the windblown dust test (5.5.1) uses the same nozzle and distance with at least 170 L/min (45 gal/min). Flow is the parameter that most labs underestimate: 240 L/min at the nozzle needs a pump and supply line sized for it, not a building tap. We supply the 1 in NEMA 4X test nozzle and a 350 GPM water booster for exactly this flow.

Dust tests (5.5): Types 3, 3S, 5, 12 and 13

Three different tests hide behind the word dust. The windblown test (5.5.1) blasts dry Portland cement with compressed air at 620 to 690 kPa onto seams and joints, or uses the hose method instead. The circulating dust test (5.5.2.1) fills an airtight chamber of at least 0.169 m³, and at least 150 % of the enclosure volume, with at least 1.5 kg of cement per m³ for five minutes. The settling dust test (5.5.2.2) uses at least 0.85 kg/m³ with the blower cycled 15 s on and 30 s off for seven cycles. Each dust test has a water-based alternate for vented enclosures: atomized water at 200 kPa (method A) or 170 kPa (method B), 11.4 L/h, sprayed at the seams. The dust in NEMA 250 is cement, not the talc of IEC 60529, so an IP5X/IP6X chamber is a different instrument.

Icing, corrosion, submersion and oil

  • External icing (5.6): water at 0 to 3 °C is sprayed while the room is cooled to −7 to −3 °C, until 20 mm of ice forms on a 25 mm test bar, then held for 3 hours. Enclosures with no external cavities that trap water need not be tested.

  • Corrosion (5.8 to 5.10): 24 h salt spray for indoor Types, 600 h compared with G90 galvanized steel for outdoor Types, and 200 h compared with passivated AISI 304 for the X Types and 6P. Enclosures in AISI 302, 303, 304, 305, 309 or 316 stainless steel are deemed to comply.

  • Temporary submersion (5.11): the top of the enclosure 1.8 m under water for 30 minutes, or an equivalent pressure difference.

  • Prolonged submersion (5.12): 24 hours, or the alternate internal pressurization at 40 kPa held for 24 hours.

  • Oil exclusion (5.13): for Type 13, against spraying and seepage of oil and non-corrosive coolants.

Practical points

Test the enclosure as it will be installed: conduit fitted and torqued, gaskets and external operators in place. Record the flow or pressure at the nozzle, not at the pump. A non-vented enclosure that passes the hosedown test is also considered to meet the drip, rain and windblown dust requirements, so the order of testing can save time. Finally, keep the edition in mind: the clause numbers here are those of NEMA 250-2018 and the corresponding UL 50E text.