top of page
ormity-logo-1600px.png
IPX5 and IPX6 jet nozzle set in SS316L stainless steel, IEC 60529 Fig. 6

IPX3, IPX4, IPX5 and IPX6 Test Nozzles: A Practical Guide to IEC 60529 Handheld Water Tests

Nov 3
4 min read

Handheld nozzles are the most widely used water-ingress tools in IEC 60529 testing. They cover four of the second-numeral codes: IPX3 (spraying water), IPX4 (splashing water), IPX5 (water jets) and IPX6 (powerful water jets). They are used mainly where the specimen is too large, too heavy or permanently installed to go under an oscillating tube or into a chamber.

The values below are those given in IEC 60529 and reproduced in our datasheets. Always check them against the edition of the standard called up by your product standard.

Spray nozzle or jet nozzle

IEC 60529 defines two handheld devices. The spray nozzle of Fig. 5 (method b of clauses 14.2.3 and 14.2.4) produces a soft, wide shower for IPX3 and IPX4. The hose nozzle of Fig. 6 (clauses 14.2.5 and 14.2.6) produces a concentrated jet for IPX5 and IPX6. They are not interchangeable: the geometry of each is specified in the standard, and the test result depends on it.

IPX3 / IPX4 spray nozzle (IEC 60529 Fig. 5)

The spray nozzle is a shower head of about 100 mm diameter with 121 holes of Ø 0.5 mm: one central hole, 24 holes on the inner circle at 30° and 96 holes on the outer circle at 15°. A counterweighted moving shield limits the spray for IPX3 and is removed for IPX4.

  • Water flow: 10 L/min ± 5 %

  • Water pressure: 50–150 kPa, adjusted to obtain the flow

  • Spray distance: 300–500 mm

  • Test duration: 1 min per m² of enclosure surface, minimum 5 min

  • Spray angle: IPX3 ± 60° with shield; IPX4 ± 180° without shield

The flow is the controlled quantity, not the pressure. That is why our IPX3 IPX4 Spray Nozzle is available with a flow meter in the handle and an integrated pressure gauge, so the operator can hold 10 L/min during the whole test. Use demineralized or filtered water: 0.5 mm holes clog quickly, and a partly blocked head changes the spray pattern without it being obvious.

The oscillating tube (method a) is normally used for small and medium specimens; the nozzle is intended for large or fixed specimens that cannot be placed under a tube. If your specimens fit under a tube, see our oscillating spray testers and the free IPX3 / IPX4 sizing tool.

IPX5 / IPX6 jet nozzles (IEC 60529 Fig. 6)

IPX5 and IPX6 use the same type of hose nozzle with different orifice diameters and flows:

  • IPX5: nozzle Ø 6.3 mm, 12.5 L/min ± 5 %; core of the stream at 2.5 m: circle of Ø 40 mm

  • IPX6: nozzle Ø 12.5 mm, 100 L/min ± 5 %; core of the stream at 2.5 m: circle of Ø 120 mm

  • Distance to specimen: 2.5–3 m

  • Test duration: 1 min per m² of enclosure surface, minimum 3 min

The jet is directed at the enclosure from all practicable directions. The flow is set with a ball valve and read on the pressure gauge, and the core of the stream is checked at 2.5 m. A nozzle whose bore is worn or out of tolerance produces a different core diameter at the same flow, which is why dimensional verification matters.

Our Jet Nozzle Set IPX5 / IPX6 is machined in SS316L stainless steel following the internal geometry of Fig. 6, with a stainless steel / Delrin™ handle, ball valve, hose connection and pressure gauge. Nozzles are sold individually or as a set.

Flow measurement

Every handheld test in IEC 60529 is defined by a flow with a ± 5 % tolerance. A pressure reading alone does not prove the flow, because the pressure needed depends on hose length, fittings and nozzle condition. In practice:

  • Measure the flow with a flow meter installed in the supply line, for example our water flow control and magnetic flow measurement system, which covers IPX1 to IPX6.

  • Stabilise the supply. Mains pressure fluctuates; a buffer tank or booster pump keeps the flow steady for the whole test.

  • Record the flow at the start and at the end of each test, and keep it in the test report.

Calibration and traceability

Ormity nozzles are available with an optional ISO/IEC 17025 dimensional certificate issued by an accredited third-party laboratory. Versions without the ISO/IEC 17025 option are supplied with a Factory Calibration Report. For periodic re-verification of nozzles, probes and fixtures, see our ISO/IEC 17025 dimensional calibration service.

Road vehicles and North America

For road vehicles, ISO 20653 also uses IPX3, IPX4, IPX5 and IPX6 tests (and adds codes such as IPX6K), and our nozzles are listed for these codes in their datasheets. In North America, enclosure ratings are usually defined by NEMA 250 and UL 50E, which use their own apparatus rather than the IEC nozzles. For those tests, see our UL 50E spray test apparatus, the NEMA 4X test nozzle and the UL RT100F, RT100C and RT100L spray nozzles.

Before each test

  • Correct nozzle for the code (Fig. 5 for IPX3/IPX4, Fig. 6 for IPX5/IPX6), with a valid calibration record.

  • IPX3: shield fitted; IPX4: shield removed.

  • Flow set and verified: 10, 12.5 or 100 L/min ± 5 %.

  • Distance: 300–500 mm (IPX3/IPX4) or 2.5–3 m (IPX5/IPX6).

  • Duration calculated from the enclosure surface (1 min/m²), not less than the minimum.

  • Clean, filtered or demineralized water.

For laboratories: Technical Note 02: Verifying IPX3–IPX6 Handheld Nozzles and Water Flow gives the step-by-step flow and nozzle verification procedure, with worked examples and a record template.

FAQ

Can I use the IPX5 nozzle for IPX6 by increasing the pressure?

No. IPX6 requires the Ø 12.5 mm nozzle at 100 L/min. The orifice diameter is part of the definition of the test.

Is the spray nozzle equivalent to the oscillating tube?

Both are methods defined by IEC 60529 for IPX3 and IPX4. The nozzle is intended for specimens that cannot be tested under a tube; check whether your product standard specifies one method.

Why is my core-of-stream check failing at the correct flow?

The most common causes are a worn or damaged orifice, debris in the nozzle and an unstable supply. Inspect the nozzle and verify its dimensions.

Do I need an ISO/IEC 17025 certificate?

Accredited laboratories normally require traceable equipment. The ISO/IEC 17025 dimensional certificate option provides it; otherwise a Factory Calibration Report is supplied.

Contact

Send us your specimen dimensions and the codes you need to test, and we will recommend a configuration. Contact Ormity or browse the Support Center & Downloads.

Comments


Commenting on this post isn't available anymore. Contact the site owner for more info.