top of page
Ormity Inc.
Admin
More actions
Profile
Join date: Aug 25, 2026
Posts (33)
Nov 6, 2026 ∙ 3 min
Drip Box Nozzles: Why Needles Fail and Threaded Stainless Micro-Nozzles Last (IPX1 / IPX2)
A drip box is only as good as its drip points. IEC 60529 asks for a regular grid of drops above the specimen, at a measured rainfall of 1 mm/min for IPX1 and 3 mm/min for IPX2. The manifold, the water supply and the calibration all matter, but the hundreds of small parts that actually form the drops are where most drip boxes go wrong. This technical note explains why, and why we made a different choice.
1
0
Nov 4, 2026 ∙ 5 min
NEMA Enclosure Types 3R, 4, 4X, 12 and Others: Which Test Proves Each Rating (NEMA 250 / UL 50E)
A NEMA Type is not a list of features. It is a promise that the enclosure passed a defined set of tests. A Type 3R box was tested in rain, a Type 4X box was tested under a hose and in salt spray, and a Type 12 box was tested against circulating dust. If you build or certify enclosures for North America, the Type tells you exactly which tests to run. This note goes through each Type and the test behind it, using the clause numbers of NEMA 250-2018. UL 50E and CSA C22.2 No. 94.
7
0
Nov 3, 2026 ∙ 4 min
Technical Note 05: Reliable CTI and PTI Results to IEC 60112 – Practice in the Laboratory
Two laboratories can test the same material to IEC 60112 and report CTI values 50 V or more apart. The method is simple on paper, but it depends on details that are easy to let slip: the shape of the electrode edges, the size of the drops, the cleanliness of the solution, the timing.
3
0
bottom of page