IPX1 and IPX2 Drip Test: How to Choose and Size a Drip Box (IEC 60529)
The dripping water tests are the first two levels of water protection in IEC 60529. IPX1 checks protection against vertically falling drops; IPX2 checks protection against drops when the enclosure is tilted up to 15°. The set-up is simple, but two points are often overlooked: the drip box must cover the specimen during its movement, not only at rest, and the rainfall must be measured.
What IEC 60529 requires
The drip box (clauses 14.2.1 and 14.2.2, Fig. 3) produces drops from a regular grid of nozzles above the specimen. The two codes differ in rainfall and specimen position:
IPX1: rainfall 1 (+0.5) mm/min for 10 min, specimen on a turntable rotating at 1 rpm.
IPX2: rainfall 3 (+0.5) mm/min for 4 × 2.5 min, specimen tilted 15° in each of four positions.
The rainfall is expressed as a height of water per minute, which makes it independent of the box size. It must be verified, not assumed.
Why the drip box must be larger than the specimen
On a turntable, the specimen rarely sits exactly on the axis of rotation, and in IPX2 the 15° tilt moves its upper parts outward. A specimen tilted 15° needs about 100 mm of extra drip area because of this eccentric movement. If the box only covers the specimen at rest, part of the enclosure leaves the rain during the test, and the result is no longer valid.
Note also that the usable area of a drip box is smaller than its outer dimensions: on Ormity manifolds, the usable area equals the manifold outer size minus 10 mm per side.
Our free IPX1 / IPX2 sizing tool takes your specimen dimensions, turntable eccentricity and tilt into account and suggests the smallest suitable box. The drip box SKU simulator then translates the result into an order code.
How an Ormity drip box is built
Nozzle grid: 20 × 20 mm
Nozzles: stainless steel M5 threaded micro-nozzles, Ø 0.4 mm orifice, individually replaceable and ultrasonic-cleanable
Manifold: SS316L, modular in 500 × 500 mm sections, hydraulically balanced
Sizes: 250 × 250 mm to 2000 × 2000 mm
Installation: wall, ceiling, adjustable frame or integrated in a chamber
Water: demineralized or filtered
The balanced manifold keeps the rainfall uniform over the whole area, including on large boxes. The micro-nozzles are threaded, so a blocked nozzle can be removed, cleaned and refitted without replacing a plate. Spare M5 micro-nozzles are available.
The drip box is a precipitation unit only: rotation for IPX1 and the 15° tilt for IPX2 are produced by an external table such as our heavy-duty turntable. For a complete, ready-to-run station, see the IPX1 / IPX2 Integrated Test System, and for floor-standing installation the drip box stand.
Standard sizes
Drip boxes are available in 250 × 250, 250 × 500, 500 × 500, 500 × 1000, 500 × 1500, 750 × 750, 1000 × 1000, 1000 × 1500, 1000 × 2000, 1500 × 1500, 1500 × 2000 and 2000 × 2000 mm. All order codes are listed on the drip box product page.
Verifying the rainfall
The rainfall rate should be checked when the box is installed and periodically afterwards, by collecting the water over a known area and time. See our IPX1 / IPX2 pluviometer page for rainfall verification. Keep the readings with your equipment records: they are the evidence that the test conditions were met.
Beyond IEC 60529: other standards using drip tests
IEC 60034-5: rotating machines, dripping water
IEC 60598-1: luminaires, clause 9.2
IEC 60947-1: Annex C
UL 1561: drip test, with dedicated drip box sizes of 1000 × 1000, 1500 × 1500 and 2000 × 2000 mm
MIL-STD-810H Method 506.6: Procedure III (drip, > 280 L/m²/h, holes on a 20–25.4 mm pattern) and Procedure I (overlapping spray nozzles at about 276 kPa), in 500 × 500 mm versions
For laboratories: Technical Note 01: Verifying the Rainfall of an IPX1 / IPX2 Drip Box gives the complete rainfall verification procedure, flow targets for every box size and an uncertainty budget.
FAQ
Can one drip box do both IPX1 and IPX2?
Yes. The box provides the rainfall; the flow is adjusted to 1 or 3 mm/min, and the table provides rotation (IPX1) or 15° tilt (IPX2).
How much larger than my specimen should the box be?
It depends on the footprint, the eccentricity on the turntable and the tilt. As a guide, a specimen tilted 15° needs about 100 mm of extra drip area. Use the sizing tool for your exact case.
Why demineralized water?
The micro-nozzles have a 0.4 mm orifice. Mineral deposits reduce or deflect the drops and make the rainfall non-uniform.
Can the drip box be installed inside a chamber?
Yes. The modular manifold can be mounted on a wall, a ceiling, an adjustable frame or integrated into a test chamber.
Contact
Send us your specimen dimensions and the standards you test to, and we will size the box with you. Contact Ormity or visit the Support Center & Downloads.