Technical Note 05: Reliable CTI and PTI Results to IEC 60112 – Practice in the Laboratory
Two laboratories can test the same material to IEC 60112 and report CTI values 50 V or more apart. The method is simple on paper, but it depends on details that are easy to let slip: the shape of the electrode edges, the size of the drops, the cleanliness of the solution, the timing.
This note collects the checks and habits that make CTI and PTI results repeatable. It follows IEC 60112:2020 (edition 5.0). Electrode geometry, force, gap and drop mass are quoted from the standard. Check the drop height, the short-circuit current tolerance and the voltage-step sequence against your copy of the standard before adopting them in your procedure.