top of page
Balanced Objects

DNDC529 Titan Series

 

Next-Generation Dust Ingress Testing

 

Engineered for Compliance. Built for Laboratories.

The DNDC529 Titan Series represents the latest generation of IP5X and IP6X dust ingress test chambers, engineered for laboratories that require repeatable, certification-grade testing conditions.

Developed in strict accordance with IEC 60529, the system is also compatible with:

  • ISO 20653 – Road vehicle sealing protection

  • IEC 60068-2-68 – Environmental dust testing

Unlike traditional chambers based on mechanical dust agitation, the Titan Series uses controlled airflow dynamics and vortex suspension to maintain stable dust concentration without structural vibration.

The result is quiet, stable, and highly repeatable dust ingress testing.

 

A New Standard in Dust Ingress Testing

Conventional dust chambers often rely on mechanical shaking or agitation motors to suspend talc.

The Titan Series introduces a vortex-based recirculation architecture, designed to:

  • Maintain uniform dust concentration

  • Eliminate internal dead zones

  • Preserve stable airflow conditions

  • Ensure homogeneous dust suspension

This approach allows the chamber to deliver reliable and repeatable IP5X and IP6X classifications.

Designed Around the Physics of Dust

Dust ingress testing is not simply blowing talc into a chamber.

Valid testing requires strict control of:

  • Dust concentration

  • Suspension uniformity

  • Specimen occupancy ratios

  • Vacuum extraction stability

  • Repeatable environmental conditions

The Titan Series airflow architecture maintains homogeneous suspension across the entire chamber volume, ensuring reliable exposure conditions for the tested specimen.

 

Compliance-Centric Engineering

The DNDC529 Titan Series supports testing under the following international standards:

  • IEC 60529 — IP5X / IP6X dust ingress protection

  • IEC 60068-2-68 — Environmental dust testing procedures

  • ISO 20653 — Road vehicle sealing protection

  • IEC 60335-1 Annex X — Appliance dust resistance testing

The chamber design strictly respects specimen occupancy limits defined in IEC 60529.

IEC 60529 Occupancy Limits

  • Maximum specimen volume ≤ 33% of usable chamber volume

  • Maximum specimen floor coverage ≤ 33%

ISO 20653 Occupancy Limits

  • Maximum specimen volume ≤ 25%

  • Maximum specimen floor coverage ≤ 50%

Respecting these limits is essential for valid certification testing — a requirement frequently ignored by low-cost systems.

 

Titan Series Model Range

ModelGross VolumeRecommended Talc Load¹Maximum Floor Load
DNDC529/0.5500 L1.0 kg20 kg
DNDC529/1.01000 L2.0 kg35 kg
DNDC529/2.02000 L4.0 kg50 kg
DNDC529/44000 L8.0 kg75 kg
DNDC810-MIL-S1600 L1.2 kg50 kg
DNDC810-MIL-S21000 L2.0 kg80 kg

¹ Based on the standard 2 kg/m³ concentration specified in IEC 60529.


Higher concentrations can be configured when required by specific procedures.

Silent. Stable. Laboratory-Ready.

The Titan Series operates at:

≤ 72 dB(A) measured at 1 meter

Unlike agitation-based systems:

  • No mechanical shaking

  • No structural resonance

  • No frame stress from agitation motors

Instead, optimized centrifugal airflow maintains dust suspension while preserving structural stability — ideal for laboratories and continuous industrial operation.

 

Intelligent Automation Platform

Each DNDC529 Titan Series chamber integrates a PLC-based automation system designed for traceable and repeatable testing.

Control Features

  • Programmable test cycles

  • Automatic vacuum monitoring

  • Leak detection via extraction rate analysis

  • USB data logging (Excel / SCADA compatible)

  • Adjustable post-test stabilization delay

  • Automatic retry logic if vacuum thresholds are not reached

Testing becomes procedure-driven rather than operator-dependent.

 

Electrical Specifications

  • Supply voltage: 220–240 V AC

  • Frequency: 50 / 60 Hz

  • Maximum current: 10 A

  • Typical power consumption: < 2.2 kW

  • Industrial-grade electrical architecture

 

Built for Accredited Laboratories

The DNDC529 Titan Series is designed to integrate seamlessly into ISO 17025 laboratory environments and third-party certification workflows.

 

Optional Configurations

  • Multi-language touchscreen PLC

  • MODBUS / RS485 / Ethernet TCP/IP connectivity

  • External dust collection modules

  • HEPA exhaust filtration systems

  • ISO 17025 calibration package

  • On-site commissioning and operator training

 

Why the Titan Series Leads

Many dust chambers focus primarily on cost reduction.

The Titan Series focuses on test validity and certification reliability.

It was engineered to:

  • Respect normative occupancy limits

  • Maintain controlled dust concentration

  • Ensure homogeneous dust suspension

  • Deliver repeatable and auditable results

When IP ratings matter, chamber physics matters.

 

Request Technical Consultation

Selecting the correct chamber volume depends on:

  • Specimen dimensions

  • Occupancy ratios

  • Certification requirements

 

Contact ORMITY Engineering for guidance on chamber sizing and configuration.

 

more...

IP5X / IP6X Dust Test Chamber

SKU: DNDC529
0,00C$Preço
Quantidade
    bottom of page