top of page
ormity-logo-1600px.png
Abstract diagonal blue stripes background

PRODUCT

Home   /   Product

Inloopstofkamer 40 m³ – Titan-serie (IP5X / IP6X)

Productcode ORTYDC529-W/40
Prijs

C$ 0,00

Walk-in dust chamber for IP5X and IP6X tests on large and heavy equipment: switchgear, drives, battery and power cabinets, EV chargers. The specimen rolls in on a 4-tonne trolley through a 2.5 m double door. Ten independently controlled blowers keep the talc in suspension: suction through slotted stainless coves along the floor, the wheel channels and the central island, return through blowing coves along the ceiling and a central roof grille.

Normen

  • IEC 60529 – 13.4 IP5X and 13.5 IP6X, Category 1 and 2 (talc, 2 kg/m³)
  • IEC 60068-2-68 – Test La, method La2
  • ISO 20653 – IP5KX / IP6KX (Arizona A2 dust option)
  • Product standards that call the IEC 60529 dust test: IEC 60598-1, IEC 60034-5, IEC 61439, IEC 61851-1, IEC 60079-0 (4 kPa option)

Technische gegevens

Binnenafmetingen 3600 × 3600 × 3000 mm (W × D × H)
Effective dust volume ≈ 39.7 m³ (ducts, collectors and channels included)
Talc charge 80 kg (2 kg/m³)
Max. specimen 2000 × 2000 × 2000 mm, up to 4000 kg on the trolley
Deur Double-leaf insulated door, clear opening 2500 × 2500 mm
Stofcirculatie 10 centrifugal blowers with individual VFDs, ≈ 5100 m³/h total
Vacuum (Category 1) 0 – 2 kPa adjustable, up to 480 m³/h, totalising flow meter
Verwarming 4 kW heated stainless floor in 4 PID zones
Besturing Industrial PLC, 10.1" touch screen, IP5X / IP6X recipes, data logging, USB export
Constructie 4" PUR camlock panels, assembled on site; AISI 304 coves, floor and channels
Vermogen 480 V 3~ 60 Hz (208/230/400 V, 50/60 Hz on request), ≈ 17.5 kW
Overall dimensions ≈ 5600 × 5100 × 3500 mm, ≈ 2500 kg empty

Aantal

Testprincipe & werking

The chamber follows IEC 60529 clause 13.4: talc at 2 kg per m³ of test volume is kept in suspension around the specimen. For Category 1 enclosures the vacuum unit holds the specimen below atmospheric pressure (up to 2 kPa); the totalising flow meter and the controller apply the 2 h / 80 volumes / 8 h rule automatically. Category 2 enclosures are tested without vacuum.

The heated stainless floor keeps the talc dry and free-flowing between and during tests. Specimen power and signal cables enter through a sealed gland plate in the rear wall.

Uitvoeringen & bestelcodes

ORTYDC529-W/40 Titan walk-in dust chamber, 40 m³ (3600 × 3600 × 3000 mm internal)

Options: Arizona A2 dust for ISO 20653, 4 kPa depression for IEC 60079-0, other supply voltages. Benchtop Titan chambers from 0.5 to 2 m³: ORTYDC529/0.5, ORTYDC529/1.0, ORTYDC529/2.0.

Bestelling, kalibratie & garantie

  • Site: level concrete slab rated for the specimen and trolley load; 480 V 3~ supply (32 A feeder). Site drawing on request.
  • Installation: prefabricated panels assembled on site.
  • Kalibratie: fabriekskalibratierapport; ISO/IEC 17025-kalibratie door een extern geaccrediteerd laboratorium op aanvraag.
  • Garantie: 1 jaar.
  • Betaling: internationale bestellingen worden 100% vooraf betaald. Alle verkopen zijn definitief na 30 dagen.
  • Verzending: via externe internationale vervoerders; vraag vóór de bestelling een leveringsraming.
Laden...

Gerelateerde producten

bottom of page