Regulação do caudal de água e caudalímetro eletromagnético IPX1–IPX6
SKU ORTYFC529-120
Preço
2595,00 CA$
Water flow control and magnetic flow measurement system for setting and recording test flow in IPX1 to IPX6 tests, per IEC 60529 clauses 14.2.1 to 14.2.6.
Normas
- IEC 60529 – IPX1 to IPX6 flow requirements
- ISO 20653
Dados técnicos
| Medição | Caudalímetro magnético-indutivo |
| Application | IPX1, IPX2, IPX3, IPX4, IPX5, IPX6 |
| Água | Softened / demineralized |
| Alimentação elétrica | 24 V DC, IP65 protected |
| Inlet / outlet | 3/4" / 1/2" |
| Controlo | Manual ball valves or PLC + HMI (semi-automatic) |
Ref.: DNFC529-120 (Dunel) / ORTYFC529-120 (Ormity) – former codes: ORTY0075/120
Quantidade
Princípio de ensaio e funcionamento
Flow control panel with magnetic-inductive flow meter for drip boxes, oscillating tubes, spray nozzles and jet nozzles. Manual control by ball valves, or semi-automatic control by PLC and HMI.
Versões e códigos de encomenda
| DNFC529-120A / ORTYFC529-120A | Controlo analógico |
| DNFC529-120S / ORTYFC529-120S | Semiautomático PLC + HMI |
Encomenda, calibração e garantia
- Prazo de entrega: até 35 dias com calibração de fábrica Ormity; até 60 dias com relatório de calibração ISO/IEC 17025 (faturado à parte).
- Garantia: 1 ano, mais garantia vitalícia contra a não conformidade (excluindo revisões de normas publicadas após a data de venda).
- Pagamento: as encomendas internacionais são pagas a 100 % antecipadamente. Todas as vendas são definitivas após 30 dias.
- Envio: através de transportadoras internacionais terceiras; o tempo de trânsito depende do destino, da embalagem (caixa/palete) e do percurso de calibração. Peça uma estimativa de entrega antes de encomendar.
Ainda não há avaliaçõesCompartilhe sua opinião.