PRODUCTO
Inicio / Producto
Cámara de polvo visitable 40 m³ – Serie Titan (IP5X / IP6X)
0,00 CAD
Walk-in dust chamber for IP5X and IP6X tests on large and heavy equipment: switchgear, drives, battery and power cabinets, EV chargers. The specimen rolls in on a 4-tonne trolley through a 2.5 m double door. Ten independently controlled blowers keep the talc in suspension: suction through slotted stainless coves along the floor, the wheel channels and the central island, return through blowing coves along the ceiling and a central roof grille.
Normas
- IEC 60529 – 13.4 IP5X and 13.5 IP6X, Category 1 and 2 (talc, 2 kg/m³)
- IEC 60068-2-68 – Test La, method La2
- ISO 20653 – IP5KX / IP6KX (Arizona A2 dust option)
- Product standards that call the IEC 60529 dust test: IEC 60598-1, IEC 60034-5, IEC 61439, IEC 61851-1, IEC 60079-0 (4 kPa option)
Datos técnicos
| Dimensiones internas | 3600 × 3600 × 3000 mm (W × D × H) |
| Effective dust volume | ≈ 39.7 m³ (ducts, collectors and channels included) |
| Talc charge | 80 kg (2 kg/m³) |
| Max. specimen | 2000 × 2000 × 2000 mm, up to 4000 kg on the trolley |
| Puerta | Double-leaf insulated door, clear opening 2500 × 2500 mm |
| Circulación del polvo | 10 centrifugal blowers with individual VFDs, ≈ 5100 m³/h total |
| Vacuum (Category 1) | 0 – 2 kPa adjustable, up to 480 m³/h, totalising flow meter |
| Calefacción | 4 kW heated stainless floor in 4 PID zones |
| Control | Industrial PLC, 10.1" touch screen, IP5X / IP6X recipes, data logging, USB export |
| Construcción | 4" PUR camlock panels, assembled on site; AISI 304 coves, floor and channels |
| Potencia | 480 V 3~ 60 Hz (208/230/400 V, 50/60 Hz on request), ≈ 17.5 kW |
| Overall dimensions | ≈ 5600 × 5100 × 3500 mm, ≈ 2500 kg empty |
Cantidad
Principio de ensayo y funcionamiento
The chamber follows IEC 60529 clause 13.4: talc at 2 kg per m³ of test volume is kept in suspension around the specimen. For Category 1 enclosures the vacuum unit holds the specimen below atmospheric pressure (up to 2 kPa); the totalising flow meter and the controller apply the 2 h / 80 volumes / 8 h rule automatically. Category 2 enclosures are tested without vacuum.
The heated stainless floor keeps the talc dry and free-flowing between and during tests. Specimen power and signal cables enter through a sealed gland plate in the rear wall.
Versiones y códigos de pedido
| ORTYDC529-W/40 | Titan walk-in dust chamber, 40 m³ (3600 × 3600 × 3000 mm internal) |
Options: Arizona A2 dust for ISO 20653, 4 kPa depression for IEC 60079-0, other supply voltages. Benchtop Titan chambers from 0.5 to 2 m³: ORTYDC529/0.5, ORTYDC529/1.0, ORTYDC529/2.0.
Pedido, calibración y garantía
- Site: level concrete slab rated for the specimen and trolley load; 480 V 3~ supply (32 A feeder). Site drawing on request.
- Installation: prefabricated panels assembled on site.
- Calibración: informe de calibración de fábrica; calibración ISO/IEC 17025 por un laboratorio externo acreditado bajo pedido.
- Garantía: 1 año.
- Pago: los pedidos internacionales se pagan al 100 % por adelantado. Todas las ventas son definitivas después de 30 días.
- Envío: mediante transportistas internacionales externos; solicite una estimación de entrega antes de pedir.