Electrical contact indicator 42 V with lamp and buzzer, for access-probe tests, per IEC 60529 (40–50 V contact indicator) and IEC 61032.
Normas
- IEC 60529 – indicator 40–50 V in series with a lamp for access probes
- IEC 61032 – probes A, B, C, D, 11, 13, 18, 19
- IEC 60335-1 – electrical contact indicator
- IEC 62368-1 / IEC 60950-1
Datos técnicos
| Output test voltage | 42 V AC |
| Alimentación | 115 / 220 V AC |
| Fuse | 0.5 A |
| Signal | Lamp + buzzer |
| Conexión | Test lead with 4 mm banana plug and jaw clamp to the probe |
Ref.: DNLI042 (Dunel) / ORTYLI042 (Ormity) – former codes: DNLI042LM, ORTY335-1-800
Cantidad
Principio de ensayo y funcionamiento
Connected between the test probe and the live parts of the specimen; lamp and buzzer indicate contact with hazardous live parts during accessibility tests.
Pedido, calibración y garantía
- Plazo de entrega: hasta 35 días con calibración de fábrica Ormity; hasta 60 días con informe de calibración ISO/IEC 17025 (facturado aparte).
- Garantía: 1 año, más garantía de por vida contra la no conformidad (excepto revisiones de normas publicadas después de la fecha de venta).