PRODUCTO
Inicio / Producto
Sistema de pulverización portátil IPX9 / IPX9K – boquilla única
12.000,00 CAD
IPX9 / IPX9K handheld spray system for high-pressure hot-water tests on large specimens, per IEC 60529 clause 14.2.9, ISO 20653 and DIN 40050-9.
Normas
IEC 60529 – 14.2.9 IPX9 (handheld method)
ISO 20653 – IPX9K
DIN 40050-9
Datos técnicos
NozzleSS316L, CNC-machined internal profile per IEC 60529Pressure80–100 bar (max. 10 000 kPa)Flow rate14–16 L/min (aperture verified)Water temperature80 ± 5 °C continuousTest distance100–150 mm (ISO 20653); 175 ± 25 mm handheld per IEC 60529Impact force10–12 N (manufacturer data)HandleHeat-insulated, high-gripConnectionHigh-pressure quick-connect or G 1/2"Ref.: DNX9529-908 (Dunel) / ORTYX9529-908 (Ormity) – former codes: ORTY529-9-908, ORTY529-9-HH
Versiones
- ORTYX9529-908-1 – Indoor: electric tankless heater; requires a pre-heated water supply (60 US gal ≈ 227 L at 60 °C), raised to the 80 °C test temperature by the machine
- ORTYX9529-908-2 – Outdoor: diesel-fired heater for field tests
Cantidad
Principio de ensayo y funcionamiento
For specimens that do not fit an IPX9 chamber or its fixed 0° / 30° / 60° / 90° nozzle positions.
Pedido, calibración y garantía
- Plazo de entrega: hasta 35 días con calibración de fábrica Ormity; hasta 60 días con informe de calibración ISO/IEC 17025 (facturado aparte).
- Garantía: 1 año, más garantía de por vida contra la no conformidad (excepto revisiones de normas publicadas después de la fecha de venta).
- Pago: los pedidos internacionales se pagan al 100 % por adelantado. Todas las ventas son definitivas después de 30 días.
- Envío: mediante transportistas internacionales externos; el tiempo de tránsito depende del destino, del embalaje (caja/palé) y de la ruta de calibración. Solicite una estimación de entrega antes de pedir.