<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0"><channel><title><![CDATA[Ormity Inc.]]></title><description><![CDATA[Ormity is your solution provider for quality & safety equipment related to the most important compliance directives worldwide recognized: IEC. UL, AST]]></description><link>https://www.ormity.com/blog</link><generator>RSS for Node</generator><lastBuildDate>Fri, 14 Aug 2026 23:35:11 GMT</lastBuildDate><atom:link href="https://www.ormity.com/de/blog-feed.xml" rel="self" type="application/rss+xml"/><item><title><![CDATA[Free IPX1/IPX2 drip box sizing tool based on IEC 60529. Learn why turntable eccentricity and 15° tilt change the minimum box size, then get your model match]]></title><link>https://www.ormity.com/post/ipx1-ipx2-drip-box-sizing-guide</link><guid isPermaLink="false">6a7e6e19cae5bb2ffa11189b</guid><category><![CDATA[Compliance Test Services]]></category><category><![CDATA[Ingress Protection Degress]]></category><pubDate>Fri, 14 Aug 2026 01:25:47 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_75e56a38cb8a43d4a757ff0557cf61cb~mv2.png/v1/fit/w_1000,h_1000,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[High-Performance IPX Test Equipment: Technical Considerations for Reliable Compliance]]></title><description><![CDATA[In product manufacturing and certification, precision is not optional—it is fundamental. This is particularly true for IPX testing, where even minor deviations in test parameters can lead to non-compliance or misleading results. Ensuring that products withstand water exposure under defined conditions requires not only adherence to IEC 60529, but also the use of properly designed and calibrated equipment. This article provides a technical overview of IPX test equipment, its role in compliance...]]></description><link>https://www.ormity.com/post/high-performance-ipx-test-equipment-technical-considerations-for-reliable-compliance</link><guid isPermaLink="false">69de4a4566c8cbf1f4c11512</guid><pubDate>Tue, 14 Apr 2026 14:43:08 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_6d854c9abb254bfda37fe0822022b8fb~mv2.png/v1/fit/w_535,h_481,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[Driving Operational Excellence: Test Optimization in High-Performance Environments]]></title><description><![CDATA[In the world of manufacturing and certification, precision is not a goal—it is the foundation of the business. However, the modern challenge lies in the balance: how do you maintain rigorous analytical standards under the pressure of shrinking production timelines? Test Optimization in High-Performance Environments The answer is not to work harder, but to restructure the testing architecture. Test optimization, powered by strategic tools, is the dividing line between overwhelmed laboratories...]]></description><link>https://www.ormity.com/post/driving-operational-excellence-test-optimization-in-high-performance-environments</link><guid isPermaLink="false">69da3c77515c02011a0e689f</guid><pubDate>Sat, 11 Apr 2026 12:30:45 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_572eb5f06dde4c7b8406ea8582f526c8~mv2.png/v1/fit/w_1000,h_768,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[Evolution of Sand and Dust Testing in MIL-STD-810: From Empirical Exposure to Controlled Environmental Simulation]]></title><description><![CDATA[Environmental testing for sand and dust exposure, as defined in MIL-STD-810 Method 510, has evolved from relatively simple exposure procedures into controlled environmental simulations grounded in fluid dynamics, particle transport, and system-level reliability considerations. The progression from MIL-STD-810A through MIL-STD-810H reflects not only procedural refinement, but also a fundamental shift in testing philosophy—from qualitative exposure toward repeatable, application-tailored...]]></description><link>https://www.ormity.com/post/mil-std-810sandanddust</link><guid isPermaLink="false">69c67247653657f03d62486b</guid><pubDate>Fri, 20 Mar 2026 04:00:00 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_2db5770fe7c1434d93e360e40098fa93~mv2.png/v1/fit/w_1000,h_1000,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[Where Precision Meets Survival: Inside the New Ormity Stainless Steel Series]]></title><description><![CDATA[Engineering that survives the real world. The new Ormity stainless steel series is built to withstand extreme industrial environments, from fine talcum dust defined in IEC 60529 to abrasive mineral particles referenced in MIL-STD-810 and IEC 60068. Designed for durability, sealing integrity, and uncompromising performance where reliability matters most.]]></description><link>https://www.ormity.com/post/where-precision-meets-survival-inside-the-new-ormity-stainless-steel-series</link><guid isPermaLink="false">69b00f91709b661fe632cb92</guid><category><![CDATA[Industrial Enclosures]]></category><category><![CDATA[Compliance of Safety]]></category><category><![CDATA[Environmental Protection]]></category><category><![CDATA[Ingress Protection Degress]]></category><pubDate>Tue, 10 Mar 2026 04:00:00 GMT</pubDate><enclosure url="http://video.wixstatic.com/video/d893e5_985846d8ba3247b9980efca0f5264c60/720p/mp4/file.mp4" length="0" type="video"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[Ingress Protection Testing Explained]]></title><description><![CDATA[Ingress protection testing is often associated with IEC 60529, but the reality is far more complex. This article explains how IP testing equipment connects a global network of standards including NEMA 250, UL 50E, ISO 20653 and MIL-STD-810, and why the same laboratory equipment serves multiple industries.]]></description><link>https://www.ormity.com/post/ingress-protection-testing-explained</link><guid isPermaLink="false">69a8c1a20df7a7bf5035e752</guid><pubDate>Wed, 04 Mar 2026 05:00:00 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_b183c988110d44de8714f397085f5f5a~mv2.png/v1/fit/w_1000,h_907,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[IP5X &#38; IP6X Dust Test Chambers – IEC 60529  Titan Series]]></title><description><![CDATA[Advanced Embedded Technology, Ultra-Low Noise, and Intelligent Expansion Redefine IP5X / IP6X Testing This March marks a significant milestone in environmental testing engineering. Ormity officially introduces the new DNDC529 IP5X IP6X Titan Series Dust Test Chambers , with the first units already being installed in Canada, the United States, and Europe. Designed and manufactured in Canada, the Titan Series sets a new benchmark for dust ingress testing under IEC 60529 (IP5X / IP6X)  and ISO...]]></description><link>https://www.ormity.com/post/ip5x-ip6x-dust-test-chambers</link><guid isPermaLink="false">6998e083658cc00bc06513bf</guid><category><![CDATA[Ingress Protection Degress]]></category><category><![CDATA[Environmental Protection]]></category><category><![CDATA[Industrial Enclosures]]></category><pubDate>Fri, 20 Feb 2026 05:00:00 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_2a216ecab79446afadeffdb447691f82~mv2.png/v1/fit/w_896,h_1000,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[New All-in-One Water Ingress Test Chamber – IPX Series]]></title><description><![CDATA[New All-in-One Water Ingress Test Chamber – IPX Series]]></description><link>https://www.ormity.com/post/new-all-in-one-water-ingress-test-chamber-ipx-series</link><guid isPermaLink="false">696567e73f7b9d5cbee298b7</guid><pubDate>Mon, 12 Jan 2026 21:34:39 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_b7408ca9a0964cd1bfb3aa0ba7174972~mv2.gif/v1/fit/w_1000,h_1000,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[The Role of Impact Testing Equipment in the Impact Testing Process]]></title><description><![CDATA[When it comes to ensuring the durability and safety of materials, the impact testing process is a cornerstone. But what exactly makes this process so vital? How do manufacturers, laboratories, and certification bodies guarantee that products withstand sudden forces without failure? The answer lies in the precision and reliability of the tools used - the impact testing equipment. This equipment is not just a tool; it is the gatekeeper of quality and compliance. Understanding the Impact Testing...]]></description><link>https://www.ormity.com/post/the-role-of-impact-testing-equipment-in-the-impact-testing-process</link><guid isPermaLink="false">692fb5e7ee21510c2ee6d150</guid><pubDate>Sat, 06 Dec 2025 00:12:08 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_17f4c907ebfe4efb804620e115c3bf67~mv2.png/v1/fit/w_1000,h_768,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[️ The Pendulum Hammer Test (Test Eha)]]></title><description><![CDATA[The Pendulum Hammer Test , designated as Test Eha  within the IEC 60068-2-75  standard, is the preferred method for assessing the mechanical robustness of enclosures designed to withstand high-energy impacts . Methodology and Application The Eha test utilizes a pendulum-style hammer  mounted on a rigid frame. The energy of the impact is controlled by the mass of the striking element and the angle from which it is released, resulting in a defined arc that hits the test specimen. Mechanism:  It...]]></description><link>https://www.ormity.com/post/the-pendulum-hammer-test-test-eha</link><guid isPermaLink="false">691dccc2f5cdcb8137dc18b9</guid><category><![CDATA[Impact Testing]]></category><category><![CDATA[IK Rating Standards]]></category><pubDate>Wed, 19 Nov 2025 14:10:31 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_2c6b7c69f2604aa9b3ca6f42b095fdb5~mv2.png/v1/fit/w_992,h_1000,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[⚙️ The Spring Hammer Test (Test Ehb)]]></title><description><![CDATA[The Spring Hammer Test , or Test Ehb , is the counterpart to Eha and is used to verify the resistance of an enclosure to low-energy impacts  that could result from careless handling, minor accidental drops, or everyday bumps. Methodology and Application The Ehb test utilizes a Spring Hammer , which is a handheld device that stores potential energy in a spring and releases it rapidly to deliver a defined impact pulse. Mechanism:  The device is manually pressed against the surface of the...]]></description><link>https://www.ormity.com/post/the-spring-hammer-test-test-ehb</link><guid isPermaLink="false">691dd1fb26d0d5c718e58ff8</guid><category><![CDATA[IK Rating Standards]]></category><category><![CDATA[Impact Testing]]></category><pubDate>Wed, 19 Nov 2025 05:00:00 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_c02e79dd8c8d4dcdb5c795f97866c156~mv2.png/v1/fit/w_1000,h_833,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[Understanding Electrical Tracking Resistance Tests: IEC 60112 vs IEC 60587]]></title><description><![CDATA[Understanding Electrical Tracking Resistance Tests: IEC 60112 vs IEC 60587]]></description><link>https://www.ormity.com/post/understanding-electrical-tracking-resistance-tests-iec-60112-vs-iec-60587</link><guid isPermaLink="false">692469e83ba9ce1c925168b7</guid><pubDate>Wed, 13 Aug 2025 04:00:00 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_5fd9d1affa124d689a763ad7e34a8f3e~mv2.jpg/v1/fit/w_1000,h_720,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[The Origins of Test Methods in Compliance Standards]]></title><description><![CDATA[When a product compliance standard requires a specific test, that test is rarely invented for the sake of that standard alone. Instead,...]]></description><link>https://www.ormity.com/post/the-origins-of-test-methods-in-compliance-standards</link><guid isPermaLink="false">6899faa31b5d45172bbd3a39</guid><pubDate>Mon, 11 Aug 2025 14:55:24 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_8265f48bcde04834bbe47422526fdab9~mv2.png/v1/fit/w_1000,h_1000,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[L’industrie des essais et la logique de la catastrophe : pourquoi la prévention doit précéder la certification]]></title><description><![CDATA[Tout au long de l’histoire industrielle moderne, ce ne sont pas seulement l’innovation ou le progrès technologique qui ont fait évoluer...]]></description><link>https://www.ormity.com/fr/post/l-industrie-des-essais-et-la-logique-de-la-catastrophe-pourquoi-la-pr%C3%A9vention-doit-pr%C3%A9c%C3%A9der-la-cer</link><guid isPermaLink="false">680cf4a97a112d76174c1b67</guid><pubDate>Sat, 26 Apr 2025 15:01:30 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_2c4f2a8402334c058c601cd5e4190ca6~mv2.png/v1/fit/w_1000,h_1000,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[The Testing Industry and the Logic of Catastrophe: Why Prevention Must Precede Certification]]></title><description><![CDATA[Major advances in safety and quality are rarely born from success — they are forged in the harsh lessons of catastrophe. Industrial history shows that when prevention is overlooked, the cost is paid in lives, losses, and ruins. This article explores why certification must not be a delayed reaction, but a forward-looking commitment to future realities.]]></description><link>https://www.ormity.com/post/the-testing-industry-and-the-logic-of-catastrophe-why-prevention-must-precede-certification</link><guid isPermaLink="false">680cf2656cf661ce98200d2f</guid><pubDate>Sat, 26 Apr 2025 04:00:00 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_2c4f2a8402334c058c601cd5e4190ca6~mv2.png/v1/fit/w_1000,h_1000,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[The Invisible War: How Fake Compliance Equipment Threatens Global Safety and Trust ]]></title><description><![CDATA[Not every certified device is trustworthy. When certification fails, global safety shakes. This is the invisible war few dare to see — but everyone will feel.]]></description><link>https://www.ormity.com/post/the-invisible-war-how-fake-compliance-equipment-threatens-global-safety-and-trust</link><guid isPermaLink="false">680a6cd12fb86d415a03fe91</guid><category><![CDATA[Compliance of Safety]]></category><pubDate>Thu, 24 Apr 2025 17:23:35 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_a8bac8e4b9914359ab912b8551b72c42~mv2.png/v1/fit/w_1000,h_1000,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[The Shadow of Espionage in Product Certification: Risks Beyond Borders]]></title><description><![CDATA[The Shadow of Espionage in Product Certification: Risks Beyond Borders]]></description><link>https://www.ormity.com/post/the-shadow-of-espionage-in-product-certification-risks-beyond-borders</link><guid isPermaLink="false">65b433b29dd3756237b94d67</guid><pubDate>Fri, 26 Jan 2024 05:00:00 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/11062b_f544449cd1374458a6f61ad17e610150~mv2.jpg/v1/fit/w_1000,h_1000,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[IPX3, IPX4, IPX3b e IPX4b: Métodos de Teste e Análise Abrangente]]></title><description><![CDATA[IPX3, IPX4, IPX3b e IPX4b: Métodos de Teste e Análise Abrangente]]></description><link>https://www.ormity.com/pt/post/ipx3-ipx4-ipx3b-e-ipx4b-m%C3%A9todos-de-teste-e-an%C3%A1lise-abrangente</link><guid isPermaLink="false">6513eed1ddc179e3f5379e4c</guid><pubDate>Wed, 27 Sep 2023 09:11:02 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_673be5d44b5147dfbd47d9aa59a6f4a6~mv2.png/v1/fit/w_1000,h_1000,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[Exploring IPX3, IPX4, IPX3b, and IPX4b Test Methods: A Comprehensive Analysis]]></title><description><![CDATA[Exploring IPX3, IPX4, IPX3b, and IPX4b Test Methods: A Comprehensive Analysis]]></description><link>https://www.ormity.com/post/exploring-ipx3-ipx4-ipx3b-and-ipx4b-test-methods-a-comprehensive-analysis</link><guid isPermaLink="false">651290279cf321bea9fc26ba</guid><category><![CDATA[Compliance Test Services]]></category><category><![CDATA[Compliance of Safety]]></category><pubDate>Tue, 26 Sep 2023 09:38:39 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/d893e5_673be5d44b5147dfbd47d9aa59a6f4a6~mv2.png/v1/fit/w_1000,h_1000,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item><item><title><![CDATA[Product Safety and Protectionism: The Risks Faced by the West Due to Failures in Equipment Testing]]></title><description><![CDATA["In developing countries, corruption compromises testing equipment validation, risking product safety and regulatory credibility."]]></description><link>https://www.ormity.com/post/product-safety-and-protectionism-the-risks-faced-by-the-west-due-to-failures-in-equipment-testing</link><guid isPermaLink="false">65105b957a557175ead051cc</guid><category><![CDATA[Compliance of Safety]]></category><pubDate>Sun, 24 Sep 2023 15:58:35 GMT</pubDate><enclosure url="https://static.wixstatic.com/media/11062b_0a5c18c328d6470ead944e9e3c394533~mv2_d_7360_4912_s_4_2.jpg/v1/fit/w_1000,h_1000,al_c,q_80/file.png" length="0" type="image/png"/><dc:creator>Dunel Atlantic</dc:creator></item></channel></rss>